MG-Cars.info

Welcome to our Site for MG, Triumph and Austin-Healey Car Information.

Recommendations

Parts

MG parts spares and accessories are available for MG T Series (TA, MG TB, MG TC, MG TD, MG TF), Magnette, MGA, Twin cam, MGB, MGBGT, MGC, MGC GT, MG Midget, Sprite and other MG models from British car spares company LBCarCo.

MG MGF Technical - Failure to 'superlock'

a few weeks ago i had to take my 2001 1.8i back to the garage as the drivers door would not open after remote unlocking. The passenger door was fine. The garage replaced the locking mechanism for me & said "its been a problem on very few 'F's". They told me i would have no problems now that the mechanism was replaced, until last friday when the same thing happened!!!!! Once again i took it to the garage where they were able to release the door, but now the car will not 'Superlock'. They said it was an electrical problem & ive to take it in & leave it with them for the day next Tuesday. Anyone else had this problem with theirs? & is it really electrical?? I thought maybe some sort of mechanical problem with the length rod which runs from your internal handel to the lock, if it is adjustable???
Any comments / views appreciated.
Thanks.
quikstu

Stu,
Do you want pictures?

The internal handle (door lock pin?) is a straight rod, and does not need adjusting
The internal handle (door handle?) is on a length of wire, which cannot be adjusted

Lack of superlocking is usually because the alarm thinks one or more doors are open - do the internal lights still operate correctly?
The key lock barrel is connected by a metel rod which could be out of alignment (not sure how, or what it would do if so) check you can lock and unlock the car using the key. Try disconnecting the battery if the electrics overrides you.
It is quite possilble that the problem was with the wireing, the newer type locks do seem to expect you to drape the connector in the bottom of the door, which can fill up with muck (and water). If the connector is corroded then you might see this problem (and wobbleing the contacts may make it go away for a few days)

Will
Will Munns

When mine was doing this, the wire to the boot lid light had become chaffed and was shorting to ground. Result - boot light on all the time and wouldn't superlock.

- Andy
S6 AJG
Andy Gilhooley

thanks will. i'll try your suggestions today.
quikstu

Will,

got one email with 5megs pictures.
Thank you. My congrats they are GREAT !!!
I'll need some hours to host them.
Will be back if done.

BTW for the electronic guys.
The switches are from CHERRY. Hope on replacement abilities though :))
http://www.cherrycorp.com/
sh*t site, not worth to look up :(
Form DB is a standard for the subminiature housing

Will, we need to know about the switch force.
Is it: 0.15 Newton or 0.25 Newton ?
If you got a letter wage, then you could check this force :)

BTW this switches are availiable also in waterprotected version IP67 !
If I have all data, then a sample order from my favourite distributor should be no problem :)
Have you got a Fax ? I'll send the catalogue pages then. (german, but wjo cares)

Regards
Dieter
Dieter Koennecke

Dieter,
I've got a torque wrench, but it doesn't go down that low!
argh! if I had known how quickly you could find the switches then I wouldn't have paid £65 to get the door mech from Rover!

The switches had degraded externaly as well as internally (on one of them the contact had rusted away)

Also I think that I will not be able to tell properly the force as the internals have rotted.

Will
Will Munns

Once pain is the others gain :)

I promise to send switches if we find out. You can repair your slot then and keep it or sell it off as second hand.

No, not a torque wrench ;)
you only need to verify whether it's 150 Gramm or 250 gramm to push down the button. Any known weight or letter wage will do if one of them still works. At last we could open one broken and one new and compare the size of the small coil-spring inside.

Refering to one of the pictures.

No 1) C-NC switch with enhanced red knob (9mm hight)
No 2) C-NC/NO switch green standard knob
No 3) C-NC switch ?knob?

(NC = Normally close, NC = Normally closed, C = common)

Is No 3 with equal knob size as No 2 ?
It looks like damaged though and pushed in ?

The connections look like 2.8mmx7.3mm blades.
Is this right ?
Or are they 1.3mm x 3.1mm solder PCB solder connections ?
Or are they 2.8mm x 3.5mm solder conn. with hole ?
Distance between the connections is 7.5mm (15mm) in any way.

From the catalogue in my hands I would say:
Options:

Cherry P/N for standard button (height 9.3mm from fixture hole to top of button)
DB1C-B1AA (150 gramm, 2.8mm blade conn.)
DB2C-B1AA (250 gramm, 2.8mm blade conn.)

IP67 versions are the same heightbut not with 2.8mm blade :)
DC1C-A1AA (200 gramm, 2.8mm short solder conn.)

I think any other will do as well, but the long red is not listed :(((

More soon.

Dieter
Dieter Koennecke

So whats's the "Master Race" working on tonight then Dieter?
Mega

So it's true, then "Mega" (sic). You really ARE a little racist twat...
Steve Clark

Will,

see here for figure 7
http://info.digikey.com/T021/V5/653.pdf

http://www.deltron-roxburgh.com/switch/cherry/subminiature.shtml
UK supplier http://www.deltron-roxburgh.com

So far the purchase manager ;)

Dieter
Dieter Koennecke

webside, a kind of ;).. only a picture collection and thanks again to Will. Yours are great.
http://www.mgfcar.de/door_slot

tired now.
Dieter
Dieter Koennecke

This thread was discussed between 06/03/2002 and 08/03/2002

MG MGF Technical index

This thread is from the archives. Join the live MG MGF Technical BBS now